Specifications
- Non-Electronic ESE
- Designed & tested as per NF C 17-102 (2011) standard.
- ΔT = 30 μsec (Triggering Time Advance Delta T).
- 100 KA (10/350 μSec) lightning current & 200 KA peak current tested in HIZAL (Turkey, Europe) lab.
- No use of battery or external power source.
- 304L (Inox) Stainless Steel design— suitable for any environmental conditions.
- Suitable for use with a variety of down conductors¬tape/strip, round conductor, isolated / insulated cables etc.
- 20 years warranty.
Protection radius as per NF C 17-102 (2011)
Mast Height h(m)
|
Level I (Very High)
|
Level II (High)
|
Level III (Medium)
|
Level IV (Standard)
|
2
|
20
|
22
|
25
|
29
|
3
|
29
|
34
|
39
|
43
|
4
|
38
|
44
|
51
|
57
|
5
|
48
|
55
|
63
|
71
|
6
|
48
|
55
|
64
|
72
|
8
|
49
|
56
|
65
|
74
|
10
|
49
|
57
|
66
|
75
|
20
|
50 |
59
|
70
|
81
|
30
|
50
|
59
|
72
|
85
|
40
|
50
|
59
|
72
|
85
|